服务热线:400-033-7715 吉林变频器|长春变频器|白城变频器|松源变频器|白山变频器|辽源变频器|四平变频器|通化变频器|廷吉变频器   | 专业变频器维修中心 |


变频器控制柜_变频器|鸿宝专注于变频领域及变频控制系统

变频器控制柜_变频器|鸿宝专注于变频器及变频控制系统
网站首页 > 变频器 > 施耐德变频器

    施耐德-ATV610-160KW变频器

    • 参考价格:

    产品特性主要信息range of productAltivar Easy 610product or component typeVariable speed driveproduct specific applicationFan, pump, compressor, conveyordevice short nameATV610variantStandard versionproduct de

    1. 概述
    2. 技术/原理
    3. 型号/尺寸
    4. 价格/图片
    5. 服务热线:400-033-7715

    产品特性


    主要信息
    range of product
    Altivar Easy 610

    product or component type
    Variable speed drive

    product specific application
    Fan, pump, compressor, conveyor

    device short name
    ATV610

    variant
    Standard version

    product destination
    Asynchronous motors

    mounting mode
    Cabinet mount

    EMC filter
    Integrated conforming to EN/IEC 61800-3 category C3 with 50 m maximum

    IP degree of protection
    IP20

    type of cooling
    Forced convection

    supply frequency
    50...60 Hz (+/-5 %)

    network number of phases
    3 phases

    [Us] rated supply voltage
    380...415 V (- 15...10 %)

    motor power kW
    160 kW normal duty
    132 kW heavy duty

    motor power hp
    250 hp normal duty
    200 hp heavy duty

    line current
    284 A at 380 V normal duty
    261 A at 415 V normal duty
    237 A at 380 V heavy duty
    224 A at 415 V heavy duty

    prospective line Isc
    50 kA

    apparent power
    187.6 kVA at 415 V normal duty
    161 kVA at 415 V heavy duty

    continuous output current
    302 A at 2.5 kHz normal duty
    250 A at 2.5 kHz heavy duty

    maximum transient current
    332 A during 60 s normal duty
    375 A during 60 s heavy duty

    asynchronous motor control profile
    Constant torque standard
    Variable torque standard
    Optimized torque mode

    output frequency
    0.0001...0.5 kHz

    nominal switching frequency
    2.5 kHz

    switching frequency
    1...8 kHz adjustable

    discrete input logic
    16 preset speeds

    communication port protocol
    Modbus serial

    option card
    Slot A : communication card Profibus DP V1
    Slot A : digital or analog I/O extension card
    Slot A : relay output card


    补充信息
    output voltage
    <= power supply voltage

    motor slip compensation
    Adjustable
    Automatic whatever the load
    Can be suppressed
    Not available in permanent magnet motor law

    acceleration and deceleration ramps
    Linear adjustable separately from 0.01 to 9000 s
    S, U or customized

    braking to standstill
    By DC injection

    protection type
    Motor : thermal protection
    Motor : motor phase break
    Drive : thermal protection
    Drive : overheating
    Drive : overcurrent between output phases and earth
    Drive : overload of output voltage
    Drive : short-circuit protection
    Drive : motor phase break
    Drive : overvoltages on the DC bus
    Drive : line supply overvoltage
    Drive : line supply undervoltage
    Drive : line supply phase loss
    Drive : overspeed
    Drive : break on the control circuit

    frequency resolution
    Display unit : 0.1 Hz
    Analog input : 0.012/50 Hz

    electrical connection
    Control, screw terminal : 0.5...1.5 mm²
    Line side, screw terminal : 2 x 95...3 x 120 mm²
    Motor, screw terminal : 2 x 95...3 x 120 mm²

    type of connector
    1 RJ45 (on the remote graphic terminal) for Modbus serial

    physical interface
    2-wire RS 485 for Modbus serial

    transmission frame
    RTU for Modbus serial

    transmission rate
    4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial

    type of polarization
    No impedance for Modbus serial

    number of addresses
    1...247 for Modbus serial

    method of access
    Slave

    supply
    External supply for digital inputs : 24 V DC (limits : 19...30 V), <= 1.25 mA (overload and short-circuit protection)
    Internal supply for reference potentiometer (1 to 10 kOhm) : 10.5 V DC +/- 5 %, <= 10 mA (overload and short-circuit protection)

    local signalling
    1 LED red for presence of voltage
    2 LEDs for local diagnostic
    1 LED yellow for embedded communication status
    2 LEDs dual colour for communication module status

    width
    320 mm

    height
    852 mm
    1159 mm with IP21 conformity kit

    depth
    390 mm

    product weight
    82 kg

    analogue input number
    3

    analogue input type
    Software-configurable voltage AI1, AI2, AI3 : 0...10 V DC, impedance 30 kOhm, resolution 12 bits
    Software-configurable current AI1, AI2, AI3 : 0...20 mA, impedance 250 Ohm, resolution 12 bits
    Software-configurable temperature probe or water level sensor AI2, AI3

    discrete input number
    6

    discrete input type
    Programmable as pulse input DI5, DI6 0...30 kHz : 24 V DC (limits : <= 30 V)
    Programmable as logic input DI1...DI6 : 24 V DC (limits : <= 30 V), impedance 3.5 kOhm

    input compatibility
    Level 1 PLC conforming to EN/IEC 61131-2, logic input DI1...DI6
    Level 1 PLC conforming to IEC 65A-68, pulse input DI5, DI6

    discrete input logic
    Positive logic (source) : DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
    Negative logic (sink) : DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
    Positive logic (source) : DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)

    analogue output number
    2

    analogue output type
    Software-configurable voltage AQ1, AQ2 : 0...10 V DC,impedance > 470 Ohm, resolution 10 bits
    Software-configurable current AQ1, AQ2 : 0...20 mA,impedance < 500 Ohm, resolution 10 bits

    sampling duration
    Analog input AI1, AI2, AI3 : 5 ms (+/- 0.1 ms)
    Analog output AQ1, AQ2 : 10 ms (+/- 1 ms)
    Discrete input DI1...DI6 : 2 ms (+/- 0.5 ms) configurable
    Pulse input DI5, DI6 : 5 ms (+/- 1 ms) configurable

    accuracy
    Analog input AI1, AI2, AI3 : +/- 0.6 % for a temperature variation 60 °C
    Analog output AQ1, AQ2 : +/- 1 % for a temperature variation 60 °C

    linearity error
    Analog input AI1, AI2, AI3 : +/- 0.15 % of maximum value
    Analog output AQ1, AQ2 : +/- 0.2 %

    relay output number
    3

    relay output type
    Configurable relay logic R1 : fault relay NO/NC, electrical durability 100000 cycles
    Configurable relay logic R2 : sequence relay NO, electrical durability 100000 cycles
    Configurable relay logic R3 : sequence relay NO, electrical durability 100000 cycles

    refresh time
    Relay output R1, R2, R3 : 5 ms (+/- 0.5 ms)

    minimum switching current
    Relay output R1, R2, R3 : 5 mA at 24 V DC

    maximum switching current
    Relay output R1, R2, R3 on resistive load (cos phi = 1 : 3 A at 250 V AC
    Relay output R1, R2, R3 on resistive load (cos phi = 1 : 3 A at 30 V DC
    Relay output R1, R2, R3 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 A at 250 V AC
    Relay output R1, R2, R3 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 A at 30 V DC

    isolation
    Between power and control terminals

    insulation resistance
    > 1 mOhm at 500 V DC for 1 minute to earth


    环境
    noise level
    76 dB conforming to 86/188/EEC

    power dissipation in W
    3270 W (forced convection) at 380 V, switching frequency 2.5 kHz

    operating position
    Vertical +/- 10 degree

    electromagnetic compatibility
    1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
    Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
    Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
    Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

    pollution degree
    2 conforming to EN/IEC 61800-5-1

    vibration resistance
    1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6
    1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

    shock resistance
    6 gn during 11 ms conforming to IEC 60068-2-27

    relative humidity
    5...95 % without condensation conforming to IEC 60068-2-3

    ambient air temperature for operation
    -15...45 °C without derating
    45...60 °C with derating factor

    operating altitude
    1000...4800 m with current derating 1 % per 100 m
    <= 1000 m without derating

    environmental characteristic
    Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
    Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3

    standards
    EN/IEC 61800-3
    EN/IEC 61800-3 environment 2 category C3
    EN/IEC 61800-5-1
    IEC 60721-3

    product certifications
    REACH

    marking
    CE


    信息来源:abc.chossoni.com


    TAG:   变频器

    信息来源:abc.chossoni.com


    TAG:   变频器

    信息来源:abc.chossoni.com


    TAG:   变频器

    信息来源:abc.chossoni.com


    TAG:   变频器

    信息来源:abc.chossoni.com


    TAG:   变频器